Air Particulate Channel
Channel Category: air_particulate
Monitors the concentration of particulate matter (PM1, PM2.5, PM10) in the air, providing insights into air quality and pollution levels.
Property Constraints
At least one property from each of the following groups must be present:
detectedorconcentration
Optional Properties
| Property | Data Type | Range/Values | Unit | Permissions |
|---|---|---|---|---|
detected | Bool | - | - | RO (Read-Only) |
concentration | Float | 0–1000 | µg/m³ | RO (Read-Only) |
mode | Enum | pm1, pm2_5, pm10 | - | RO (Read-Only) |
active | Bool | - | - | RO (Read-Only) |
fault | Uchar | 0–255 | - | RO (Read-Only) |
tampered | Bool | - | - | RO (Read-Only) |
Property Details
detected
Binary detection state (true = detected)
concentration
Measured concentration level
mode
Operating mode selection
active
Indicates if the channel/sensor is currently active and functioning
fault
Fault code or diagnostic indicator (0 = no fault)
tampered
Indicates if the device has been tampered with