Hardware Inputs & Wall Controllers
Smart Panel provides first-class support for physical hardware inputs — including wall switches, momentary push buttons, multi-button scene controllers, rotary dials, and potentiometers.
Whether you are using a dedicated wall switch module (such as a Shelly Plus i4), smart relays with switch inputs (Shelly Pro 4PM), smart dimmers (Shelly Pro Dimmer 2PM), Zigbee battery remotes, or embedded panel buttons, Smart Panel normalizes their signals into a unified event architecture.
Hardware inputs operate with sub-millisecond local latency. Push-button clicks are delivered directly through the internal event bus without waiting for database writes or cloud round-trips.
Input Types & Semantics
Smart Panel organizes hardware inputs into three standard channel categories:
1. Push Buttons (button)
Momentary push buttons, tactile switches, and scene keypads emit ephemeral event occurrences.
- Properties:
event(EVENT_ONLY): Emits discrete gestures such aspress,double_press,triple_press,long_press,down(press down edge), andup(release edge).detected(READ_ONLY, optional): Indicates whether the button is actively held down (true/false).
- No Stale State: Because button events are ephemeral, they do not retain a static value in storage. Reconnecting devices or restarting the backend will never replay past button clicks.
2. Binary Inputs (binary_input)
Bistable physical switches, wall rocker switches, or contact sensors represent persistent state.
- Properties:
state(READ_ONLY): Reflects the current electrical contact position (truefor closed/on,falsefor open/off).
- Stateful Storage: Transitions are stored and queryable via the REST API and WebSocket channels.
3. Analog Inputs (analog_input)
Continuous physical controls like rotary dials, sliders, or 0–10V potentiometers.
- Properties:
value(READ_ONLY): Current measurement value (floating-point number or integer).
Architectural Guarantees
Channel-Scoped Deduplication
Hardware protocols (such as Shelly Gen 2 RPC or Zigbee) may retransmit packets during network disruptions. Smart Panel applies deduplication scoped strictly by deviceId + channelId + sourceOccurrenceId.
- Duplicate packets arriving within a sliding debounce window are automatically dropped.
- Simultaneous presses on distinct channels with the same sequence counter are preserved independently.
- Repeated rapid clicks without external sequence IDs are always treated as separate, valid occurrences.
Actuator and Input Isolation
On mixed devices (e.g. smart dimmers or smart relays with physical switch terminals):
- Issuing commands to the actuator (turning on a light or adjusting brightness) never triggers spurious button events.
- Physical input events do not directly mutate actuator state in the devices core; occurrences are delivered as events only, reserving actuator state changes and action routing for future automation capabilities.
Integration Matrix
| Integration | Supported Channels | Gestures / Events | Notes |
|---|---|---|---|
| Shelly Next-Gen | button, binary_input, analog_input | btn_down, btn_up, single_push, double_push, triple_push, long_push | Shelly Plus i4, Pro 4PM, Pro Dimmer 2PM |
| Shelly v1 | button, binary_input | S (single), SS (double), SSS (triple), L (long) | Shelly 1, 2.5, Dimmer 2 |
| Home Assistant | button, binary_input, analog_input | press, double_press, long_press | Synchronized via HASS entity events |
| Homey SHS | button, binary_input | press, double_press, long_press | Mapped from Homey device capabilities |
| HomeKit | button | single_press, double_press, long_press | Stateless programmable switch profile |
| WLED | button, analog_input | press, long_press, value | ESP32 physical buttons and rotary dials |
| Zigbee2MQTT | button, binary_input, analog_input | single, double, triple, hold, release | Philips Hue Dimmer, IKEA remotes, etc. |
| reTerminal | button | press, down, up | Built-in physical buttons F1–F4 |
| Virtual Devices | button, binary_input, analog_input | Passthrough from source | Allows mirroring or aliasing physical inputs |
| Third-Party | button, binary_input, analog_input | Configurable | Ingestion via HTTP REST / Webhooks |
Testing & Simulation
The Simulator Plugin provides full emulation of hardware inputs for testing and automated scenarios.
You can simulate physical occurrences via the REST endpoint:
POST /api/v1/plugins/simulator/simulator/:deviceId/simulate-occurrence
Content-Type: application/json
Authorization: Bearer <TOKEN>
{
"data": {
"channel_id": "<BUTTON_CHANNEL_UUID>",
"event": "press"
}